| Application
note # 6 |
Sample
Champion
|
MLS
and pink filter. Why use it?
In
some circumstances, it could be useful to have a pink noise
generator, especially when an octave or third-octave
frequency analysis is
required. Sample Champion
can pink-filter the MLS signal. Here below there are some examples
(with "loop back" configuration).

Figure
1 - "Flat" impulse response

Figure
2 - "Flat" frequency response from the
impulse response plotted in figure 1

Figure
3 - Third octave analysis of the "flat" frequency
response plotted in figure 2; the difference between
adjacent 1/3 octave bands is equal to 1 dB

Figure
4 - Impulse response measured in the same conditions of figure
1, but using a pink-filtered MLS signal

Figure
5 - Frequency response from the
impulse response plotted in figure 4

Figure
6 - Third octave analysis of the frequency
response plotted in figure 5
Download
PDF file (125K) Shift-click
to download
Back to Application Notes
|